ASHRAE energy audit levels and how to choose the right one

Climeaction
Newsroom
16 November 2026
6 min read
On this page
Share this article
Energy audits
Scope your audit with an engineer
We plan and run ASHRAE energy audits for US buildings and plants, then carry the findings into design and delivery.
The big picture
Pick the ASHRAE audit level by the decision in front of you: Level 1 to screen, Level 2 to build a capital plan, Level 3 to commit major capital.
For facilities directors, energy managers and plant leads at US offices, labs, campuses and manufacturing sites.

Most audit quotes name a level, and most buyers sign without knowing what that level buys. The three ASHRAE energy audit levels differ in depth, cost and what you can do with the report afterwards. Choosing the wrong one means either paying for analysis you do not need or ending up with a report that cannot support a budget request.

After reading this guide you can say what each level delivers, check whether a local law has already set the level for you, and write an audit scope that fits your building or plant.

One ASHRAE standard defines all three audit levels

ASHRAE Standard 211, the Standard for Commercial Building Energy Audits, is the reference. The American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) published it in 2018 and reaffirmed it in 2023. It replaced the older Procedures for Commercial Building Energy Audits that many city rules and incentive programs used to cite.

The standard does three things that matter to a buyer. It sets a common scope of work for Levels 1, 2 and 3. It sets the minimum rigor of analysis at each level. And it sets minimum reporting requirements, so two auditors quoting the same level should be quoting comparable work. The ASHRAE fact sheet on Standard 211 sets this out.

Each level builds on the one before it. A Level 2 audit includes everything in Level 1, and a Level 3 audit includes everything in Level 2. Every level requires a site visit and starts with a preliminary energy use analysis: at least 12 consecutive months of energy data, and up to three years, used to benchmark the building’s energy use intensity (EUI), which is annual energy use divided by gross floor area.

Level 1 shows where the savings are likely to be

A Level 1 audit is a screening exercise. The U.S. Department of Energy’s Federal Energy Management Program (FEMP) defines it as benchmarking, a review of the utility rate structure, a site survey, an analysis of how spaces are used, and a list of no-cost and low-cost measures plus capital improvements worth a closer look.

What a Level 1 audit does not give you is numbers you can take to a budget meeting. Under Standard 211, savings and costs at this level are qualitative. That is fine when the question is where to look first. It is not fine when the question is how much to spend.

Level 1 typically suits portfolios with many similar buildings, sites that have never been audited, and owners deciding which building to study in more depth.

Level 2 gives you projects you can put in a capital plan

Level 2 is the workhorse. FEMP’s definition covers building operation and control settings, a breakdown of energy end uses, efficiency and renewable energy measures, and economic paybacks for every measure. That end-use breakdown is the step that separates Level 2 from a walk-through. The auditor accounts for where the energy goes before proposing what to change.

Standard 211 also asks the auditor to sort ideas with care. A practical measure is one that is technically feasible. A recommended measure is a practical measure that has been checked for interactive effects with the other measures and judged to give the owner a net benefit. Interactive effects matter: a lighting retrofit cuts cooling load but can raise heating load, so two measures rarely save the sum of their separate estimates.

A Level 2 report gives you a ranked list of measures with costs, savings and simple payback. For most owners it is the right level for a first serious audit.

Level 3 is for capital decisions you cannot afford to get wrong

Level 3 is the most rigorous level. FEMP describes it as requiring detailed building modeling or measurement, including seasonal and occupant variations, a life-cycle cost analysis (LCCA), and an analysis of uncertainty in the implementation. Standard 211 also requires the auditor to carry out a risk assessment at this level.

That rigor costs time and money, so it is usually reserved for a small number of large measures: a central plant replacement, a steam to hot water conversion, an electrification project, or a measure financed against its savings. When those savings later have to be proven through measurement and verification, a Level 3 baseline makes that work easier. Our post on why phased energy efficiency upgrades need proof covers that step.

That end-use breakdown is the step that separates Level 2 from a walk-through.
Level 2 audits

Check whether a local law has already chosen the level

In New York City, the choice is partly made for you. Local Law 87 requires buildings over 50,000 gross square feet to complete an energy audit and retro-commissioning and to file an Energy Efficiency Report once every ten years, by 31 December of the building’s due year. The due year follows the last digit of the building’s tax block number.

The Department of Buildings rules set the audit at a minimum equivalent to an ASHRAE Level 2 audit under Standard 211-2018, and the report must include every section of the standard’s Level 2 report outline. Missing the filing is a Class 2 violation, with a $3,000 penalty for the first year and $5,000 for each further year.

Other cities and utility programs set their own levels, and Standard 211 lets jurisdictions adapt its procedures and reporting forms. Read the rule or program terms before you request quotes, so the scope you buy is the scope you need. Owners facing emissions limits can also read our post on the Local Law 97 2030 deadline.

Manufacturing plants need more than a building audit

Standard 211 is a commercial building standard. Its end-use scope covers the envelope, lighting, HVAC, controls, water and pumping, onsite generation, data centers, plug loads and similar systems. Industrial processes, agricultural processes and irrigation are outside its scope.

For a plant, that means an ASHRAE Level 2 audit of the building alone can miss the largest loads: compressed air, process heating and cooling, steam, drying and the motors on the line. The ASHRAE level is still a useful way to set the depth of the building portion, but the process systems need their own scope, typically written into the same engagement. Ask for both, and ask the auditor to show how the two add up to the metered site total. Read more on how we work with manufacturing sites.

Questions facility teams ask us

Can we go straight to Level 3? You can, but most owners should not. A Level 2 audit tells you which measures justify the extra cost of Level 3 analysis. Spending that effort on every measure is rarely worthwhile.

Does a Level 1 audit count for compliance? Only where the rule says so. ASHRAE notes that its Building EQ portal supports a Level 1 audit whose reports can be used to show compliance with audit requirements. New York City’s Local Law 87 asks for at least Level 2.

How much data do we need before the site visit? At least 12 consecutive months of utility bills for every fuel, and up to three years if you have them. Interval data from the utility or a building management system typically makes a Level 2 or Level 3 audit faster and more accurate.

Does an audit cover decarbonization? Not by default. Standard 211 now includes an optional Building Decarbonization Assessment that builds on an existing energy audit. Ask for it if you face emissions limits or a net zero target.

Choose your level in four steps

  • Name the decision. Screening a portfolio points to Level 1. Building a capital plan points to Level 2. Committing to one large project points to Level 3.
  • Check the rules. Confirm whether a city law, utility program or lender sets a minimum level or report format.
  • Gather twelve months of data first: bills for every fuel, floor areas, equipment lists and any interval data.
  • Scope process loads separately if you run a plant, and ask for one reconciled picture of the site.

Getting the level right is the cheapest decision in the whole project. Our advisory team can scope and run the audit and carry its results into the projects that follow, or you can talk to us about your site.

Rules checked against official sources on 16 November 2026.

Key insight
Buy the level your decision needs

The audit level should match the decision on the table, not the size of the building. Settle the decision and the rules first, and the right level usually follows.

Written by
Climeaction
Newsroom
Climeaction is a B Corp certified sustainability consultancy working across Ireland and the United States. We combine engineering and data to help businesses reduce carbon, save energy and increase profits.
Latest insights

Continue exploring

Legislation
Climeaction •
3 min read
Decarbonization
Climeaction •
3 min read
Legislation
Climeaction •
3 min read
Climeaction

Through a combination of data-driven insights and innovative approaches, we work closely with you to reduce carbon, save energy, and increase profits.

NSAI Certified: Energy, ISO 50001:2018
NSAI Certified: Quality, ISO 9001:2015
Certified B Corporation

Our Locations

United States

77 Summer Street
Boston, MA, USA

+1 617 982 7731 | info@climeaction.com

Ireland

11 South Mall
Cork City, T12 CYF7

19 High Street
Kilkenny, R95F2KD

+353 (21) 2455199 | info@climeaction.com

© 2026 Climeaction. All Rights Reserved